The flexor tendons of the hand are very fine and complex structures; these transmit the muscle forces to provide to the fingers a great range of motion (ROM), strength, touch, and precision[1]. The hands, as a functional organ, are responsible for a wide variety of activities of daily life, especially in professionals and athletes. In this context, the hands are quite always exposed to injuries and accidents. Currently, the most frequent causes of hand trauma include partial and total tendon ruptures[2]. According to current statistics reported by the Italian Hospital Discharge Registry, from 2016 to 2019, approximately 30,000 cases of tendon injuries have been reported per year, of which 30% correspond to injuries of the flexor and extensor tendons of the hands[3].
Based on the type of the hand tendon injury, the damage may cause a significant disability or loss of finger function. The challenge in the treatment is originated from the repair of the flexor tendons injuries, both the flexor digitorum profundus (FDP) and the flexor digitorum superficialis (FDS). In particular, management of zone II injuries where is required to re-establish the continuity of the tendons, the gliding mechanism, and preserve the pulleys[4]. At the moment, suture thread is the gold standard treatment strategy for repair ruptured tendons[5]. However, after surgery reconstruction, regardless of the suture techniques and materials, the main problems occurring are caused by (1) inadequate grasping of the tendon by the suture thread (slippage and gap formation), (2) suture knot failures (potential repair failure sites, and gliding resistance within the synovial sheath and pulleys) and (3) suture thread rupture (insufficient tensile strength). Besides, unwanted fibrous scar-like tissue formation, associated with persistent inflammation and excessive remodeling (poor functional properties of the healing tendon lead to re-rupture), and adhesions between the healing tendon and surrounding soft tissues (reduced ROM) are the primary causes of repair failure and the most common reasons for re-operation after the initial repair[6-8].
Owing to complications associated with suture thread (1-3), in the last years, a wide range of methods and options have been proposed, ranging from repair devices, barbed sutures, and scaffolds to regenerative medicine approaches. Nevertheless, several of them exhibit variable and inconsistent outcomes[9, 10]. There is a major interest in developing a solution that enables improvement, accelerates, and standardizes tendon repair but to date, replace suture thread remains an open challenge to solve in the field of hand reconstructive surgery.
As mentioned before, another limitation in the tendon healing process is the higher fibrous scar-like tissue which exhibits a lower ratio of the collagen type I[11]. As a consequence, the tendon thickens and stiffens to overcome the lower mechanical strength, and hence tissue quality is reduced[12]. Over the past few years, the concept of scarless healing has recently become of interest to researchers. However, the mechanisms underlying scarless healing have still to be elucidated. Undoubtedly, further research is needed to offer reliable clinical treatments[13]. On the other hand, the adhesions are part of the healing process and almost inevitably produce functional disability. These may occur between the FDP and FDS tendons as well as between the tendons and flexor sheath, thus increasing gliding resistance and stress at the repair site[14]. Independent of the solution (suture threads, devices, etc.), minimizing adhesions is key to the success of a flexor tendons repair; the improved rehabilitation protocols involving early postoperative mobilization have shown promising patient outcomes[15]. Indeed, early mobilization promotes intrinsic healing, reduces the severity of adhesion formation, and minimizes extrinsic scarring after tendon repair[16]. Therefore, the surgeon's method must combine precise atraumatic tissue management along with providing a strong repair solution that enables an early post-operative motion protocol[17, 18]. The present study aims to create a patient-specific hand model to simulate the passive rehabilitation movement on the index finger, quantifying the amount of FDP tendon excursion and the stress experienced during simulated flexion.
Three-dimensional (3D) anatomical models are based on digital imaging and communications in medicine (DICOM) format; these datasets are obtained from several acquisition modalities such as computerized tomography (CT) and magnetic resonance (MR)[19]. The great availability of accessible datasets to generate 3D anatomical models has enabled actively conducted research as well as combining imaging segmentation, 3D modeling, and Finite Elements (FE) analysis[20, 21]. The hand model used in this study was created from a CT dataset available in the Embodi3d online library containing several medical image datasets and 3D printable models for research and learning use[22]. The acquisition data from an unknown patient included a continuous image sequence of the right hand in the supine position, with the acquisition parameters, are reported in Table 1.
The segmentation and 3D reconstruction were performed by Materialise Mimics innovation suite 21.0 (Materialise, Leuven, Belgium). The bone segmentation was performed, selecting a preset threshold range between [-863 to 1013] HU (Hounsfield Unit)[23]. Owing to nearly similar contrast values among soft tissue structures (tendons, sheaths, pulleys) and surrounding tissue (muscles, fat, and skin) was necessary to set the segmentation threshold manually between the threshold range [-978 to -870] HU. We hypothesized that the selected threshold range coincided with tendinous sheaths’ paths through which the tendons and pulleys are assembled. The general view of this process is displayed in Figure 1.
The models of the flexor tendons and pulleys A1-A3 were generated in the Rhinoceros 6.0 (Robert McNeel & Associates, Washington, United States), and Materialise 3-Matic research suite 13.0 Computer-Aided Design (CAD) systems, these were located on the volar plate. The cross-section areas (CSA) and defined paths of the tendinous sheaths obtained from CT scans were used to define the profile sketches of the tendons and curves on the CAD system. To calculate the CSA of the tendons, we approximated their cross-sectional area based on an elliptical approximation (Area = Π × D1 × D2 /4), considering the mean of the horizontal diagonal (D1=4.10). The mean vertical diagonal (D2) was reduced by approximately 50%, estimating the oval-shaped of the tendons as reported in Table 2. In addition, the design uniform shaping of the FDP tendons enables the gliding mechanism and the free excursion through the pulleys during flexion in the in-silico model.
The A1 and A3 pulleys were designed using the surfaces of the proximal phalanx and the metacarpal; this process requires 3D creating and editing tools. A2 and A4 pulleys were not considered because these do not affect ROM[14, 24]. Figure 2 (A) shows the overlapping of the approximate cross-sectional areas of the sheath, the tendon, as well as the estimated 50% reduction thereof. At the end of the segmentation, reconstruction, and modeling process, in Figure 2 (B), the anatomical model of the right hand is shown, which will be used in the simulation.
Some hypotheses were considered to simplify the complexity of the physiological environment and the interactions between anatomical structures. For the present study, only the flexion of the index finger was considered. The other complementary structures were included in the model with a frozen rigid structural behavior. Besides, not all the synovial sheaths surrounding the tendons were considered; their lubrication effect during the excursion of the internal tendon was modeled as a frictionless contact with all the structures involved in the contact region. All assembled structures were exported as standard for the exchange of product model (STEP) files from Materialise 3-Matic research suite 13.0. The completed model meshed in the ANSYS R19.2 (Swanson Analysis Systems, Inc. Houston, PA, United States) Computer-aided engineering (CAE) system, where the data post-processing, deformations, and stresses were calculated. The flexor tendons, pulleys, and bones were considered as linear orthotropic materials, the tetrahedral formulation and the type of unit were 10-node elements (TED10) were set to fit geometries with 744 elements in the distal, medial, proximal phalanxes, and metacarpal bones, 1506 elements in the pulleys A1 and A3, and 296 elements in the FDP tendon [Figure 4]. This type of element enables the reproduction of properly curved surfaces with curved edges, owing to each edge of the volume element has mid-side nodes[25]. The general view of the right-hand model is displayed in Figure 3.
The bone (cortical-trabecular hard materials) and tendon (fibers at different length scales-connective matrix soft materials) present a complex composite hierarchical architecture with an anisotropic mechanical behavior which is difficult to model numerically[26-28]. To approximate the characterization of these composite materials, in literature, several studies consider constitutive models with isotropic responses[29-32]. The present study used more accurate findings, which are considered as a linear elastic orthotropic approximation of the material's behavior. During the simulated passive post-operative movement, all the bones of the hand were considered linear cortical, and mechanical properties were based on experimental measures, which are shown in Table 3-4[33, 34].
Aiming to mimic the FDP tendon and pulley behavior, principal structures of FE analysis in the passive flexion movement. An experimental investigation conducted by[35] employing mechanical properties of porcine flexor tendons, which have been demonstrated to present similar mechanical behavior(36, 37) was considered for the simulation. The FDP tendon (fibers and matrix) and pulleys were defined as isotropic linear elastic materials from the rule of mixture approximation. The mechanical properties are presented in Table 5. In addition, an isotropic stress limit of 107 MPa was considered based on the cadaver study[38].
The passive post-operative movement of the idealized index finger model was simulated by applying the following conditions. An increasing ramp load of 0 to 9 N[39] (3.6X, 1.2Y, -8.2Z) was applied for 3 seconds to the FDP tendon. The 3 ° and 5 ° rotations were imposed in correspondence with the distal and proximal interphalangeal (DIP-PIP) joints, respectively. Fixed support was set to the lower surface of the metacarpal bone to block the dorsum and enable flexion of the finger. Likewise, the main rotation of 70 ° was applied on the metacarpal-phalangeal (MCP) joint according to the rehabilitation protocol[15] [Figure 4]. All angles of rotation were imposed considering the physiological ROM of each joint of the index finger[40]. Frictionless tendon-pulley contacts were assigned to replicate the action of synovial fluid within the sheath enabling the gliding mechanism. Besides, a bonded contact was imposed at the bone-to-FDP tendon contact region to replicate the distal osteotendinous junction.
Figure 5 shows total deformation in the index finger model; the highest value is present in the distal phalanx with a resultant deformation of 96.0 mm corresponding to the MCP rotation, as well the lowest value is located in the metacarpal bone. Besides, the FDP tendon presents an excursion of 10.1 mm during passive post-operative flexion starting from a supine position. Figure 6 shows the stress map of the model. The high-stress region is observed around the pulleys-FDP tendon contact regions. In particular, the A1 pulley exhibits the maximum principal stress of the model with a 58.7 MPa on the posterior FDP tendon surface. In contrast, the anterior FDP tendon surface presents compression stress of -1.6 MPa. The pulley A3 shows the same stress distribution pattern as that A1 pulley. But with the lowest values corresponding to 8.2 MPa and -0.5 MPa, respectively. Table 6 shows values corresponding to maximum-minimum deformation and stress of the FDP tendon pulley contact regions.
This FE analysis aimed to assess the excursion and stresses arising in the FDP tendon-pulley assembly when an increasing load was applied simulating the passive postoperative flexion. The total deformation of the index finger showed a well-distributed trend in the model from the distal phalanx to the proximal metacarpal region, demonstrating a correct ROM as well as an appropriate orientation of the structures. The resultant deformations in the model showed the FDP tendon-pulley assembly can fully transmit appropriate movement to the extremity of the distal phalanx, rotating around the axis corresponding to the MCP joint. Figure 7 shows the free-body analysis of the index finger model during a partial rotation in the YZ plane. Starting from the supine position (0, 0) and imposing MCP rotation in X, from DIP - PIP to DIP’-PIP' positions, there was a greater deformation in the most distal zone of the index finger model (YDIP' > YPIP' and ZDIP' > ZPIP'). This explains the greater deformation is located in the bone-tendon attachment (96 mm).
Several cadaver studies using different methods to assess FDP tendon excursion (i.e., position markets and digital dynamometer) have reported a resultant deformation varies from 8 to 11 mm[15] [41, 42]. The FDP Tendon excursion obtained in this FE simulation is consistent with the experimental results. The metacarpal bone does not present deformations owing to the fixed supports imposed.
Regarding the stress map, it may be observed that the index finger bones presented the lowest values; this is mainly because the transmission of the load was performed efficiently by the pulley’s mechanism. A similar system occurs in the fishing rod, a rigid element; however, unlike this, the bones of the hand present joints that enable the flexion of the finger and the tendon excursion. Indeed, the highest-stress values were present in the contact regions between the A1-A5 pulleys and FDP tendon; this demonstrates the importance of the structures, keeping FDP tendon attached to the finger bone during the complete ROM[43].
The early motion of rehabilitation is essential after tendon repair to facilitate intrinsic tendon healing while minimizing extrinsic adhesion formation and scar tissue formation. The purpose of this study was to create a patient-specific model of the hand and to replicate the passive rehabilitation movement on the index finger to quantify the amount of FDP tendon excursion and stress experienced during simulated flexion at 70 °. The simulated motion in the in-silico model resulted in normal FDP tendon excursion. Our predictive result coincides with the experimental studies present in the literature. The FE simulation of the index finger model provided results that explain the biomechanical phenom at the contact region between the FDP tendon and A1-A5 pulleys. In particular, the stress map results showed a directly proportional relationship between the angle formed by the tendon at the MCP joint and the contact regions between the A1-A5 pulleys and the FDP tendon. A the higher the tendon angle is, the larger is the overall stress of the pulley-tendon assembly. The resultant deformations of the index finger model showed the greater deformation in the most distal zone located in the bone-tendon attachment, which was verified with the free-body analysis during a partial rotation in the YZ plane. The findings of the simulation framework proposed may potentially be used in the development and assessment of novel in-silico medical device proposals aimed at challenging FDP tendon repair in the field of hand reconstructive surgery.
The authors would like to thank the Italian Ministry of Health for providing the data about the tendon repair surgical operations performed in Italy during the period 2016-2018, as well as the University Polytechnic of Turin (Italy) for its outstanding support.
[1] R. Singh, B. Rymer, P. Theobald, and P. Thomas, “A review of current concepts in flexor tendon repair: physiology, biomechanics, surgical technique and rehabilitation.” Orthopedic reviews, vol. 7, no. 4, Dec. 28, 2015. [Online]. Available: https://doi.org/10.4081/or.2015.6125
R. Singh B. Rymer P. Theobald P. Thomas A review of current concepts in flexor tendon repair: physiology, biomechanics, surgical technique and rehabilitationOrthopedic reviews7428122015https://doi.org/10.4081/or.2015.6125
[2] G. Riley, “Chronic tendon pathology: molecular basis and therapeutic implications,” Expert Reviews in Molecular Medicine, vol. 7, no. 5, Mar. 30, 2005. [Online]. Available: https://doi.org/10.1017/S1462399405008963
G. Riley Chronic tendon pathology: molecular basis and therapeutic implicationsExpert Reviews in Molecular Medicine7530032005https://doi.org/10.1017/S1462399405008963
[3] D. generale della programmazione sanitaria, “Rapporto annuale sull’attività di ricovero ospedaliero(dati sdo 2019),” Ministero della Salute, Roma, IT, Tech. Rep., Jan. 2021. [Online]. Available: https://www.salute.gov.it/portale/documentazione/p6_2_2_1.jsp?lingua=italiano&id=3002
D. generale della programmazione sanitaria Rapporto annuale sull’attività di ricovero ospedaliero(dati sdo 2019)Ministero della Salute, RomaITTech. Rep.012021https://www.salute.gov.it/portale/documentazione/p6_2_2_1.jsp?lingua=italiano&id=3002
[4] A. Momeni, E. Grauel, and J. Chang, “Complications after flexor tendon injuries,” Hand Clinics, vol. 26, no. 2, May. 2010. [Online]. Available: https://doi.org/10.1016/j.hcl.2009.11.004
A. Momeni E. Grauel J. Chang Complications after flexor tendon injuriesHand Clinics262052010https://doi.org/10.1016/j.hcl.2009.11.004
[5] C. S. Irwin, B. G. Parks, and K. R. Means, “Biomechanical analysis of zone 2 flexor tendon repair with a coupler device versus locking cruciate core suture,” Journal of Hand Surgery, vol. 45, no. 9, Apr. 7, 2020. [Online]. Available: https://doi.org/10.1016/j.jhsa.2020.02.015
C. S. Irwin B. G. Parks K. R. Means Biomechanical analysis of zone 2 flexor tendon repair with a coupler device versus locking cruciate core sutureJournal of Hand Surgery45907042020https://doi.org/10.1016/j.jhsa.2020.02.015
[6] M. Wiig et al., “A lactoferrin-derived peptide (pxl01) for the reduction of adhesion formation in flexor tendon surgery: An experimental study in rabbits,” Journal of Hand Surgery (European Volume), vol. 36, no. 8, Jun. 23, 2011. [Online]. Available: https://doi.org/10.1177%2F1753193411410823
M. Wiig A lactoferrin-derived peptide (pxl01) for the reduction of adhesion formation in flexor tendon surgery: An experimental study in rabbitsJournal of Hand Surgery (European Volume)36823062011https://doi.org/10.1177%2F1753193411410823
[7] A. N. Nayak et al., “A mechanical evaluation of zone ii flexor tendon repair using a knotless barbed suture versus a traditional braided suture,” Journal of Hand Surgery , vol. 40, no. 7, Jun. 3, 2015. [Online]. Available: https://doi.org/10.1016/j.jhsa.2015.04.009
A. N. Nayak A mechanical evaluation of zone ii flexor tendon repair using a knotless barbed suture versus a traditional braided sutureJournal of Hand Surgery40703062015https://doi.org/10.1016/j.jhsa.2015.04.009
[8] C. J. Dy, A. Hernandez, Y. Ma, T. R. Roberts, and A. Daluiski, “Complications after flexor tendon repair: A systematic review and meta-analysis,” Journal of Hand Surgery , vol. 37, no. 3, Feb. 10, 2012. [Online]. Available: https://doi.org/10.1016/j.jhsa.2011.11.006
C. J. Dy A. Hernandez Y. Ma T. R. Roberts A. Daluiski Complications after flexor tendon repair: A systematic review and meta-analysisJournal of Hand Surgery37310022012https://doi.org/10.1016/j.jhsa.2011.11.006
[9] C. Dennis and et al., “Suture materials - current and emerging trends,” Journal of Biomedical Materials Research, vol. 104, no. 6, Feb. 10, 2016. [Online]. Available: https://doi.org/10.1002/jbm.a.35683
C. Dennis Suture materials - current and emerging trendsJournal of Biomedical Materials Research104610022016https://doi.org/10.1002/jbm.a.35683
[10] J. A. Greenberg and R. H. Goldman, “Barbed suture: A review of the technology and clinical uses in obstetrics and gynecology,” Reviews in Obstetrics & Gynecology, vol. 6, no. 3, 2013. [Online]. Available: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4002186/
J. A. Greenberg R. H. Goldman Barbed suture: A review of the technology and clinical uses in obstetrics and gynecologyReviews in Obstetrics & Gynecology632013https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4002186/
[11] F. Wu, M. Nerlich, and D. Docheva, “Tendon injuries: Basic science and new repair proposals,” EFORT Open Reviews, vol. 2, no. 7, Jul. 17, 2017. [Online]. Available: https://doi.org/10.1302/2058-5241.2.160075
F. Wu M. Nerlich D. Docheva Tendon injuries: Basic science and new repair proposalsEFORT Open Reviews2717072017https://doi.org/10.1302/2058-5241.2.160075
[12] S. Thomopoulos, W. C. Parks, D. B. Rifkin, and K. A. Derwin, “Mechanisms of tendon injury and repair,” Journal of Orthopaedic Research, vol. 33, no. 6, Jan. 29, 2015. [Online]. Available: https://doi.org/10.1002/jor.22806
S. Thomopoulos W. C. Parks D. B. Rifkin K. A. Derwin Mechanisms of tendon injury and repairJournal of Orthopaedic Research33629012015https://doi.org/10.1002/jor.22806
[13] L. M. Galatz, L. Gerstenfeld, E. Heber, and S. A. Rodeo, “Tendon regeneration and scar formation: The concept of scarless healing,” Journal of Orthopaedic Research , vol. 33, no. 6, Feb. 11, 2015. [Online]. Available: https://doi.org/10.1002/jor.22853
L. M. Galatz L. Gerstenfeld E. Heber S. A. Rodeo Tendon regeneration and scar formation: The concept of scarless healingJournal of Orthopaedic Research33611022015https://doi.org/10.1002/jor.22853
[14] B. Zafonte, D. Rendulic, and R. M. Szabo, “Flexor pulley system: Anatomy, injury, and management,” Journal of Hand Surgery , vol. 39, no. 12, Dec. 1, 2014. [Online]. Available: https://doi.org/10.1016/j.jhsa.2014.06.005
B. Zafonte D. Rendulic R. M. Szabo Flexor pulley system: Anatomy, injury, and managementJournal of Hand Surgery391201122014https://doi.org/10.1016/j.jhsa.2014.06.005
[15] A. Sapienza, H. K. Yoon, R. Karia, and S. K. Lee, “Flexor tendon excursion and load during passive and active simulated motion: A cadaver study,” Journal of Hand Surgery (European Volume), vol. 38, no. 9, 2013. [Online]. Available: https://doi.org/10.1177%2F1753193412469128
A. Sapienza H. K. Yoon R. Karia S. K. Lee Flexor tendon excursion and load during passive and active simulated motion: A cadaver studyJournal of Hand Surgery (European Volume)3892013https://doi.org/10.1177%2F1753193412469128
[16] K. F. Lutsky, E. L. Giang, and J. L. Matzon, “Flexor tendon injury, repair and rehabilitation,” Orthopedic Clinics of North America, vol. 46, no. 1, Jan. 2015. [Online]. Available: https://doi.org/10.1016/j.ocl.2014.09.004
K. F. Lutsky E. L. Giang J. L. Matzon Flexor tendon injury, repair and rehabilitationOrthopedic Clinics of North America461012015https://doi.org/10.1016/j.ocl.2014.09.004
[17] H. M. Starr, M. Snoddy, K. E. Hammond, and J. G. Seiler, “Flexor tendon repair rehabilitation protocols: A systematic review,” Journal of Hand Surgery , vol. 38, no. 9, Sep. 1, 2013. [Online]. Available: https://doi.org/10.1016/j.jhsa.2013.06.025
H. M. Starr M. Snoddy K. E. Hammond J. G. Seiler Flexor tendon repair rehabilitation protocols: A systematic reviewJournal of Hand Surgery38901092013https://doi.org/10.1016/j.jhsa.2013.06.025
[18] A. Chesney, A. Chauhan, A. Kattan, F. Farrokhyar, and A. Thomas, “Systematic review of flexor tendon rehabilitation protocols in zone ii of the hand,” Journal of the American Society of Plastic Surgeons, vol. 127, no. 4, Apr. 2011. [Online]. Available: https://journals.lww.com/plasreconsurg/Abstract/2011/04000/Systematic_Review_of_Flexor_Tendon_Rehabilitation.23.aspx
A. Chesney A. Chauhan A. Kattan F. Farrokhyar A. Thomas Systematic review of flexor tendon rehabilitation protocols in zone ii of the handJournal of the American Society of Plastic Surgeons1274042011https://journals.lww.com/plasreconsurg/Abstract/2011/04000/Systematic_Review_of_Flexor_Tendon_Rehabilitation.23.aspx
[19] E. George, P. Liacouras, F. J. Rybicki, and D. Mitsouras, “Measuring and establishing the accuracy and reproducibility of 3d printed medical models,” RadioGraphics, vol. 37, no. 5, Aug. 11, 2017. [Online]. Available: https://doi.org/10.1148/rg.2017160165
E. George P. Liacouras F. J. Rybicki D. Mitsouras Measuring and establishing the accuracy and reproducibility of 3d printed medical modelsRadioGraphics37511082017https://doi.org/10.1148/rg.2017160165
[20] A. F. Hernández and et al., “Application of 3d modeling methodology using ct scans for numerical analysis,” Revista facultad de ingeniería Universidad de Antioquia, no. 72, Sep. 2014. [Online]. Available: https://revistas.udea.edu.co/index.php/ingenieria/article/view/15747
A. F. Hernández Application of 3d modeling methodology using ct scans for numerical analysisRevista facultad de ingeniería Universidad de Antioquia72092014https://revistas.udea.edu.co/index.php/ingenieria/article/view/15747
[21] V. Chulvi, D. Cebrian, A. Sancho, and R. Vidal, “Automated design of customized implants,” Revista facultad de ingeniería Universidad de Antioquia , no. 68, Sep. 2013. [Online]. Available: http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0120-62302013000300010
V. Chulvi D. Cebrian A. Sancho R. Vidal Automated design of customized implantsRevista facultad de ingeniería Universidad de Antioquia68092013http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0120-62302013000300010
[22] (2019, Oct. 8,) Hand bst 3 1.0.0. Embodi 3D. [Online]. Available: https://www.embodi3d.com/files/file/28972-hand-bst-3/
08102019Hand bst 3 1.0.0. Embodi 3Dhttps://www.embodi3d.com/files/file/28972-hand-bst-3/
[23] N. Wake and et al., “Creating patient-specific anatomical models for 3d printing and ar/vr: a supplement for the 2018 radiological society of north america(rsna)hands-on course,” 3D Printing in Medicine, vol. 5, no. 17, Dec. 30, 2019. [Online]. Available: https://threedmedprint.biomedcentral.com/articles/10.1186/s41205-019-0054-y
N. Wake Creating patient-specific anatomical models for 3d printing and ar/vr: a supplement for the 2018 radiological society of north america(rsna)hands-on course3D Printing in Medicine51730122019https://threedmedprint.biomedcentral.com/articles/10.1186/s41205-019-0054-y
[24] G. Mitsionis and et al., “Feasibility of partial a2 and a4 pulley excision: Residual pulley strength,” Journal of Hand Surgery (European Volume), vol. 25, no. 1, Feb. 1, 2000. [Online]. Available: https://journals.sagepub.com/doi/10.1054/jhsb.1999.0332
G. Mitsionis Feasibility of partial a2 and a4 pulley excision: Residual pulley strengthJournal of Hand Surgery(European Volume)25101022000https://journals.sagepub.com/doi/10.1054/jhsb.1999.0332
[25] T. Krauthammer, “Accuracy of the finite element method near a curved boundary,” Computers & Structures, vol. 10, no. 6, Dec. 1979. [Online]. Available: https://doi.org/10.1016/0045-7949(79)90061-0
T. Krauthammer Accuracy of the finite element method near a curved boundaryComputers & Structures106121979https://doi.org/10.1016/0045-7949(79)90061-0
[26] J. Y. Rho, L. Kuhn, and P. Zioupos, “Mechanical properties and the hierarchical structure of bone,” Medical Engineering & Physics, vol. 20, no. 2, Mar. 1998. [Online]. Available: https://doi.org/10.1016/S1350-4533(98)00007-1
J. Y. Rho L. Kuhn P. Zioupos Mechanical properties and the hierarchical structure of boneMedical Engineering & Physics202031998https://doi.org/10.1016/S1350-4533(98)00007-1
[27] H. R. Screen, D. A. Lee, D. L. Bader, and J. C. Shelton, “An investigation into the effects of the hierarchical structure of tendon fascicles on micromechanical properties,” Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 218, no. 2, Feb. 1, 2004. [Online]. Available: https://doi.org/10.1243%2F095441104322984004
H. R. Screen D. A. Lee D. L. Bader J. C. Shelton An investigation into the effects of the hierarchical structure of tendon fascicles on micromechanical propertiesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine218201021998https://doi.org/10.1243%2F095441104322984004
[28] R. W. Ogden. (1997) Non-linear elastic deformations. Dover Publications, Inc. [Online]. Available: https://n9.cl/6xz7y
R. W. Ogden 1997Non-linear elastic deformationsDover Publications, Inc.https://n9.cl/6xz7y
[29] F. Elza, L. Joana, and B. Luisa, “Human femur assessment using isotropic and orthotropic materials dependent of bone density,” Polytechnic Institute of Bragança, Bragança, PT, 2009. [Online]. Available: https://bibliotecadigital.ipb.pt/handle/10198/1664
F. Elza L. Joana B. Luisa Human femur assessment using isotropic and orthotropic materials dependent of bone densityPolytechnic Institute of BragançaBragança, PT2009https://bibliotecadigital.ipb.pt/handle/10198/1664
[30] L. L. Vignoli and P. P. Kenedi, “Bone anisotropy - analytical and finite element analysis,” Latin American Journal of Solids and Structures, vol. 13, no. 1, Jan. 2016. [Online]. Available: https://doi.org/10.1590/1679-78251814
L. L. Vignoli P. P. Kenedi Bone anisotropy - analytical and finite element analysisLatin American Journal of Solids and Structures131012016https://doi.org/10.1590/1679-78251814
[31] C. Santiuste, M. Rodríguez, E. Giner, and H. Miguélez, “The influence of anisotropy in numerical modeling of orthogonal cutting of cortical bone,” Composite Structures, vol. 116, 2014. [Online]. Available: https://doi.org/10.1016/j.compstruct.2014.05.031
C. Santiuste M. Rodríguez E. Giner H. Miguélez The influence of anisotropy in numerical modeling of orthogonal cutting of cortical boneComposite Structures1162014https://doi.org/10.1016/j.compstruct.2014.05.031
[32] T. A. Carniel and E. A. Fancello, “A transversely isotropic coupled hyperelastic model for the mechanical behavior of tendons,” Journal of Biomechanics, vol. 54, Mar. 21, 2017. [Online]. Available: https://doi.org/10.1016/j.jbiomech.2017.01.042
T. A. Carniel E. A. Fancello A transversely isotropic coupled hyperelastic model for the mechanical behavior of tendonsJournal of Biomechanics5421032017https://doi.org/10.1016/j.jbiomech.2017.01.042
[33] D. Moratal. (2012) Finite element analysis - from biomedical applications to industrial developments. InTech. [Online]. Available: https://n9.cl/0axol
D. Moratal 2012Finite element analysis - from biomedical applications to industrial developmentsInTechhttps://n9.cl/0axol
[34] E. F. Morgan, G. U. Unnikrisnan, and A. I. Hussein, “Bone mechanical properties in healthy and diseased states,” Annual Review of Biomedical Engineering, vol. 20, Jun. 2018. [Online]. Available: https://doi.org/10.1146/annurev-bioeng-062117-121139
E. F. Morgan G. U. Unnikrisnan A. I. Hussein Bone mechanical properties in healthy and diseased statesAnnual Review of Biomedical Engineering20062018https://doi.org/10.1146/annurev-bioeng-062117-121139
[35] S. D. Rawson, L. Margetts, J. Wong, and S. H. Cartmell, “Sutured tendon repair; a multi-scale finite element model,” Biomech Model Mechanobio, vol. 14, May. 20, 2014. [Online]. Available: https://doi.org/10.1007/s10237-014-0593-5
S. D. Rawson L. Margetts J. Wong S. H. Cartmell Sutured tendon repair; a multi-scale finite element modelBiomech Model Mechanobio1420052014https://doi.org/10.1007/s10237-014-0593-5
[36] W. F. Mao, Y. F. Wu , Y. L. Zhou, and J. B. Tang, “A study of the anatomy and repair strengths of porcine flexor and extensor tendons: are they appropriate experimental models?” Journal of Hand Surgery (European Volume) , vol. 36, no. 8, Jul. 18, 2011. [Online]. Available: https://doi.org/10.1177%2F1753193411414117
W. F. Mao Y. F. Wu Y. L. Zhou J. B. Tang A study of the anatomy and repair strengths of porcine flexor and extensor tendons: are they appropriate experimental models?Journal of Hand Surgery (European Volume)36818072011https://doi.org/10.1177%2F1753193411414117
[37] R. G. Rodríguez and et al., “Biomechanical analysis of damaged intervertebral disc using reflective photoelasticity,” Revista facultad de ingeniería Universidad de Antioquia , no. 78, Mar. 2016. [Online]. Available: http://www.scielo.org.co/scielo.php?pid=S0120-62302016000100010&script=sci_arttext&tlng=en
R. G. Rodríguez Biomechanical analysis of damaged intervertebral disc using reflective photoelasticityRevista facultad de ingeniería Universidad de Antioquia78032016http://www.scielo.org.co/scielo.php?pid=S0120-62302016000100010&script=sci_arttext&tlng=en
[38] J. F. Weber, A. M. Agur, A. Y. Fattah, K. D. Gordon, and M. L. Oliver, “Tensile mechanical properties of human forearm tendons,” Journal of Hand Surgery (European Volume), vol. 40, no. 7, May. 4, 2015. [Online]. Available: https://doi.org/10.1177%2F1753193415584715
J. F. Weber A. M. Agur A. Y. Fattah K. D. Gordon M. L. Oliver Tensile mechanical properties of human forearm tendonsJournal of Hand Surgery (European Volume)40704052015https://doi.org/10.1177%2F1753193415584715
[39] K. Kursa, L. Lattanza, E. Diao, and D. Rempel, “In vivo flexor tendon forces increase with finger and wrist flexion during active finger flexion and extension,” Journal of Orthopaedic Research , vol. 24, no. 4, Apr. 2006. [Online]. Available: https://doi.org/10.1002/jor.20110
K. Kursa L. Lattanza E. Diao D. Rempel In vivo flexor tendon forces increase with finger and wrist flexion during active finger flexion and extensionJournal of Orthopaedic Research244042006https://doi.org/10.1002/jor.20110
[40] Y. Liu and et al., “Objective evaluation of hand rom and motion quality based on motion capture and brunnstrom scale,” IEEE/ASME (AIM) International Conference on Advanced Intelligent Mechatronics, Hong Kong, CN, 2019. [Online]. Available: https://ieeexplore.ieee.org/document/8868793
Y. Liu Objective evaluation of hand rom and motion quality based on motion capture and brunnstrom scaleIEEE/ASME (AIM) International Conference on Advanced Intelligent MechatronicsHong Kong, CN2019https://ieeexplore.ieee.org/document/8868793
[41] U. C. Ugbolue, W. H. Hsu, R. J. Goitz, and Z. M. Li, “Tendon and nerve displacement at the wrist during finger movements,” Clinical Biomechanics, vol. 20, no. 1, Jan. 1 2005. [Online]. Available: https://doi.org/10.1016/j.clinbiomech.2004.08.006
U. C. Ugbolue W. H. Hsu R. J. Goitz Z. M. Li Tendon and nerve displacement at the wrist during finger movementsClinical Biomechanics20101012005https://doi.org/10.1016/j.clinbiomech.2004.08.006
[42] Z. M. Li , S. Dun, D. A. Harkness, and T. L. Brininger, “Motion enslaving among multiple fingers of the human hand,” Human Kinetics Journals, vol. 8, no. 1, 2004. [Online]. Available: https://doi.org/10.1123/mcj.8.1.1
Z. M. Li S. Dun D. A. Harkness T. L. Brininger Motion enslaving among multiple fingers of the human handHuman Kinetics Journals812004https://doi.org/10.1123/mcj.8.1.1
[43] J. A. Parellada, A. R. Balkissoon, C. W. Hayes, and W. F. Conway, “Bowstring injury of the flexor tendon pulley system: Mr imaging,” AJR American Journal of Roentgenology, vol. 167, no. 2, 1996. [Online]. Available: https://www.ajronline.org/doi/10.2214/ajr.167.2.8686601
J. A. Parellada A. R. Balkissoon C. W. Hayes W. F. Conway Bowstring injury of the flexor tendon pulley system: Mr imagingAJR American Journal of Roentgenology16721996https://www.ajronline.org/doi/10.2214/ajr.167.2.8686601