Atmospheric corrosion revenue in Colombian transmission system

Authors

  • Juan David Molina Pontifical Catholic University of Chile
  • Fernando Villada University of Antioquia
  • Noé Mesa University of Antioquia

DOI:

https://doi.org/10.17533/udea.redin.13830

Keywords:

regulation, MOM costs, transmission system, atmospheric corrosion

Abstract

This paper describes and evaluates the regulatory mechanism implemented in Colombia for the compensation of atmospheric corrosion on the infrastructure of electric power transmission. Its present the mathematical model used for representation of atmospheric corrosion and degradation materials, plus the impact of the methodology, as well as the influence of the technical life to the regulatory life. It concluded that for areas classified as aggressive, the increase in AOM is higher than is recognized by salt contamination.

|Abstract
= 337 veces | PDF (ESPAÑOL (ESPAÑA))
= 291 veces|

Downloads

Download data is not yet available.

Author Biographies

Juan David Molina, Pontifical Catholic University of Chile

Department of Electrical Engineering. Efficient Energy Management Group – GIMEL. University of Antioquia.

Fernando Villada, University of Antioquia

Efficient Energy Management Group – GIMEL.

Noé Mesa, University of Antioquia

Efficient Energy Management Group – GIMEL.

References

XM Compañía de Expertos en Mercados S.A. E.S.P. http://www.xm.com.co/. Consultada el 24 de septiembre de 2009. DOI: https://doi.org/10.4324/9781849774451-5

J. D. Molina. Impacto de la Corrosión Atmosférica sobre la Infraestructura de Líneas de Transmisión en Colombia.” Facultad de Ingeniería. Tesis de Maestría: Universidad de Antioquia. Medellín (Colombia). 2008. pp. 52-127.

J. C. Minotas, C. E. Arroyave, A. Valencia, R. Pérez. “Avances en los Estudios de Corrosión Atmosférica en Colombia.” Rev. Fac. Ing. Univ. Antioquia. N.o 8. 1996. pp. 11. pp. 32-42.

J. Maya.”Recuperación de Herrajes y Aisladores Afectados por la Corrosión en Líneas de Alta Tensión”. IV Jornadas Latinoamericanas y I Iberoamericanas en Alta Tensión y Aislamiento Eléctrico. ALTAE. Vol. 1. Medellín, (Colombia). 1999. pp. 1-6.

Corporación para la Investigación de la Corrosión (CIC). Concepto Técnico sobre el Efecto de la Salinidad en Transmisión y Distribución de Energía Eléctrica: Cables, Postes y Aisladores. Informe Técnico (OS 120-20040037), CREG E-2004-003861. Bucaramanga (Colombia). 2000. pp. 1-19.

J. Maya.”Evaluación y Control de la Corrosión en Componentes de Torres de Líneas de Transmisión de Energía”. VII Congreso Latinoamericano y IV Iberoamericano en Alta Tensión y Aislamiento Eléctrico. ALTAE. Panamá. Vol. 1. 2005. pp. 1-6.

J. Maya.”Metodología para el Manejo Integral de la Corrosión en Líneas de Transmisión de Energía Eléctrica.” III Congreso CIER de la Energía CONCIER, Abastecimiento Energético Regional -Retos y Perspectivas-. CIER. Medellín (Colombia). Vol. 1. 2007. pp.1-7.

E. Correa, C. Botero, J. Restrepo, A. Delgado, C. Castaño, F. Echeverria.”Corrosión del acero al carbono, acero galvanizado y aluminio en diferentes atmósferas colombianas.” Revista Scientia et Technica. N.o 36. 2007. pp. 7-12.

http:/www.knobel.com/web/portal. Corrosion: Fundamentals, Testing, and Protection. Vol. 13a. 2003. pp. 196-209. Consultada el 29 de septiembre de 2009.

Grupo de Corrosión y Protección y Grupo de Investigación en el Manejo Eficiente de la Energía Eléctrica. Universidad de Antioquia. Impacto de la corrosividad atmosférica sobre la infraestructura del SEC y sobre los costos AOM Proyecto de investigación. Informe Final. Proyecto de Investigación COLCIENCIAS-CREG. Cod. 1115-06-17398. 2007. pp. 262-309.

P. R. Roberge. Handbook of Corrosion Engineering. Ed. McGraw-Hill. New York. 2000. pp. 55-85.

IEC 61165. Application of Markov techniques. 2ª. ed. Ed. International Electrotechnical Commission. Geneva (Switzerland). 2006. pp. 1-76.

S. Amari, L. McLaughlin. “Optimal Desing of a Condition-Based Maintenance Model, Reliability and Maintainability” Annual Symposium-RAMS IEEE. Los Angeles. California (USA). 2004. pp.528-533.

I. P. Siqueira. “Optimum Reliability-Centered Maintenance Task Frequencies for System Equipments.” 8th International Conference on Probabilistic Methods Applied to Power Systems PMAPS IEEE. Ames (Iowa). 2004. pp. 162-167.

Electric Power Research Institute (EPRI). Cost of Corrosion in the Electric Power Industry. EPRI TR1004662. Final report. Palo Alto (CA). October 2001. pp. 75-88.

K. Myer. Handbook of Environmental Degradation of Materials. (pp: 3-24). William Andrew Publishing. Versión disponible en Internet en: http://www.knovel.com/web/portal/browse/display?_EXT_KNOVEL_DISPLAY_bookid=1253&VerticalID=0 2005. Consultada el 29 de septiembre de 2009.

Committee on Cost of Corrosion in Japan. “Survey of Corrosion Cost in Japan”. http://www.nims.go.jp/corrosion/corrosion_cost.pdf. Consultada el 24 de septiembre de 2009.

J. D. Molina, H. Rudnick. “Transmission of Electric Energy: a Bibliographic Review.” Latin America Transactions. IEEE - Revista IEEE America Latina. Vol. 8. 2010. pp. 245-258. DOI: https://doi.org/10.1109/TLA.2010.5538399

Comisión de Regulación de Energía y Gas (CREG). http://www.creg.gov.co/html/i_portals/index.php. Consultada el 24 de Septiembre de 2009.

MME. Reglamento Técnico de Instalaciones Eléctricas. Res. 18 1294, RETIE. Ed. Ministerio de Minas y Energía. Bogotá. 2008. pp. 171-178.

Sistema Único de Información de Servicios Públicos. www.sui.gov.co. Consultada el 24 de septiembre de 2009.

Published