Touchless control module for diagnostic images at the surgery room using the Leap Motion system and 3D Slicer software

Authors

DOI:

https://doi.org/10.17533/udea.redin.n82a05

Keywords:

diagnostic imaging, human-computer interaction, image guided neurosurgery, medical informatics computing, positioning system

Abstract

During surgical procedures, it is important that the personnel (surgeon, residents, or assistants) interact with the patient avoiding any physical contact with equipment and materials that might have not been appropriately sterilized. This is done in order to prevent patient’s infections and complications after surgery. With the increased availability of diagnostic images, this technology has become indispensable in operating rooms but to maintain asepsis control of computer equipment on which the visualization programs are executed is not always possible, hindering access to personnel to information contained in the images. This paper describes the development of a system that allows the personnel to manipulate a medical imaging display program using gestures, avoiding the surgeon or the nurse to have a direct contact with the computer. The system, which requires a computer with 3D-Slicer software and Leap Motion (LM) device, allows through gestures made with the hands, to access the basic operations such as the movement between sections of a volume, to change the image size and the anatomical plane visualization; operations that are essential to the surgeon for the spatial location and decision making.

|Abstract
= 514 veces | PDF
= 339 veces|

Downloads

Download data is not yet available.

Author Biographies

Andrés Felipe Botero-Ospina, University of Antioquia

Research Group in Bioinstrumentation and Clinical Engineering (GIBIC), Department of Bioengineering, Faculty of Engineering.

Sara Isabel Duque-Vallejo, University of Antioquia

Research Group in Bioinstrumentation and Clinical Engineering (GIBIC), Department of Bioengineering, Faculty of Engineering.

John Fredy Ochoa-Gómez, University of Antioquia

Research Group in Bioinstrumentation and Clinical Engineering (GIBIC), Department of Bioengineering, Faculty of Engineering.

Alher Mauricio Hernández-Valdivieso, University of Antioquia

Research Group in Bioinstrumentation and Clinical Engineering (GIBIC), Department of Bioengineering, Faculty of Engineering.

References

R. Johnson, K. O’Hara, A. Sellen, C. Cousins, and A. Criminisi, “Exploring the Potential for Touchless Interaction in Image-Guided Interventional Radiology,” in 29th Int. Conf. Hum. Factors Comput. Syst., Vancouver, Canada, 2011, pp. 3323-3332.

L. C. Ebert, G. Hatch, M. J. Thali, and S. Ross, “Invisible touch—Control of a DICOM viewer with finger gestures using the Kinect depth camera,” J. Forensic Radiol. Imaging, vol. 1, no. 1, pp. 10-14, 2013.

A. Fedorov et al., “3D Slicer as an image computing platform for the Quantitative Imaging Network.,”Magn. Reson. Imaging, vol. 30, no. 9, pp. 1323-1341, 2012.

M. Sato et al., “Development of an image operation system with a motion sensor in dental radiology,” Radiol. Phys. Technol., vol. 8, no. 2, pp. 243-247, 2015.

A. Nishikawa et al., “FAce MOUSe: a novel human- machine interface for controlling the position of a laparoscope,” IEEE Trans. Robot. Autom., vol. 19, no. 5, pp. 825-841, 2003.

A. B. Albu, “Vision-Based User Interfaces for Health Applications : A Survey,” in Advances in Visual Computing, G. Bebis et al. (eds). Germany: Springer, 2006, pp. 771-782.

M. Spiegelmock, Leap motion development essentials, 1st ed. Birmingham, UK: Packt Publishing Ltd., 2013.

P. Garg, N. Aggarwal, and S. Sofat, “Vision based hand gesture recognition,” Int. J. of Computer, Electrical, Automation, Control and Information Engineering, vol. 3, no. 1, pp. 186-191, 2009.

K. Sabir and B. Tabor, “The molecular control toolkit: Controlling 3d molecular graphics via gesture and voice,” in IEEE Symposium on Biological Data Visualization (BioVis), Atlanta, GA, USA, 2013, pp. 49-56.

S. Webel, M. Olbrich, T. Franke, and J. Keil, “Immersive experience of current and ancient reconstructed cultural attractions,” in Digital Heritage International Congress (DigitalHeritage), Marseille, France, 2013.

Cyber Science 3D, Products. [Online]. Available: http://cyberscience3d.com/products/. Accessed on: Mar. 15, 2016.

W. Schroeder, K. Martin, and B. Lorensen, The Visualization Toolkit-30, 3rd ed. Kitware, 1996.

Leap Motion, Inc., Recalibrating your Leap Motion Controller. [Online]. Available: https://support.leapmotion.com/hc/en-us/articles/223782328-Recalibratingyour-Leap-Motion-Controller. Accessed on: Mar. 15, 2016

N. Bizzotto et al., “Leap Motion Gesture Control With OsiriX in the Operating Room to Control Imaging: First Experiences During Live Surgery,” Surg. Innov., vol. 21, no. 6, pp. 655-656, 2014.

L. Di Tommaso, S. Aubry, J. Godard, H. Katranji, and J. Pauchot, “A new human machine interface in neurosurgery: The Leap Motion (R). Technical note regarding a new touchless interface,” Neurochirurgie, vol. 62, no. 3, pp. 178-181, 2016.

Downloads

Published

2017-03-16

How to Cite

Botero-Ospina, A. F., Duque-Vallejo, S. I., Ochoa-Gómez, J. F., & Hernández-Valdivieso, A. M. (2017). Touchless control module for diagnostic images at the surgery room using the Leap Motion system and 3D Slicer software. Revista Facultad De Ingeniería Universidad De Antioquia, (82), 40–46. https://doi.org/10.17533/udea.redin.n82a05