Reproducibility of a test for the functional evaluation of dynamic and agility in elderly people
DOI:
https://doi.org/10.17533/udea.iatreia.14835Keywords:
Elderly, 8 foot up & go test, Postural Balance, ReliabilityAbstract
Background: The 8 foot up & go test assesses the dynamic balance and agility in elderly people. Its reproducibility has been evaluated in American population, but it is unknown whether it would work similarly in a different population like the Colombian.
Objective: To evaluate the test-retest reliability and agreement level of the 8 foot up & go test in a sample of older adults from Bucaramanga, Colombia.
Materials and methods: An evaluation of diagnostic tests was done in 114 elderly individuals. In the analysis, we assessed the test-retest reliability of the 8 foot up & go test by the Intraclass Correlation Coefficient (ICC 2.1) with their respective confidence intervals at 95% (95% CI). The agreement level was established by the Bland-Altman method.
Results: The test-retest reliability of the 8 foot up & go test was very good (ICC: 0.98; 95% CI: 0.98- 0.99). The agreement was good in females (mean difference [MD] = 0.04 seconds and limits of agreement [LA]: -1.27; 1.36 seconds), and in elderly institutionalized (MD = 0.04 seconds [LA]: -3.18; 3.27 seconds).
Conclusion: The 8 foot up & go test has very good reliability and good agreement in Colombian local elderly population.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
Papers published in the journal are available for use under the Creative Commons license, specifically Attribution-NonCommercial-ShareAlike 4.0 International.
The papers must be unpublished and sent exclusively to the Journal Iatreia; the author uploading the contribution is required to submit two fully completed formats: article submission and authorship responsibility.