Grounding transient response of lightning protection GTIERRAS software
DOI:
https://doi.org/10.17533/udea.redin.343242Keywords:
grounding system, overvoltages, lightning, modeling, electromagnetic compatibilityAbstract
A computer program developed in Matlab (GTIERRAS) from an electromagneticbased model is used to assess grounding impedances and the behavior of grounding electrodes of arbitrary shapes under lightning impulses. Impedance, currents and voltages, or other electric variables of the grounding system can be presented as well in frequency or in time domain with the use of Fast Fourier Transform. The generality of the model allows its use for assessing lightning overvoltages, but also for other typical transients associated with electromagnetic compatibility problems. Results show the influence of some variables on the response of grounding system and shed light on some differences that must be taken into account when applying criteria based on low frequency performance to groundings stressed by surges. Calculation examples and comparison with results from other authors are presented and analyzed so as to illustrate some grounding behaviors that by no means are evident. Effects of electrode geometry and soil resistivity, as well as of wave front and number of injection points are also investigated. Results of touch and step potentials are shown. A study of a lightning protection system is presented as an extension of the model application capabilities. Some conclusions useful for grounding system design are derived.
Downloads
References
G. Moreno, J. Valencia, F. Villada. “Modelación de puestas a tierra para simulación de sobretensiones transitorias en transmisión de energía eléctrica”. En: Revista Facultad de Ingeniería, Universidad de Antioquia. No. 25. Medellín. Abril, 2002. pp 106-116.
S. Visacro, “Modelagem de Aterramentos Elétricos”. Río de Janeiro. Tesis de Doctorado, Universidad Federal de Río de Janeiro. 1992.
A. Otero, J. Cidrás, “Frequency-Dependent Grounding System Calculation by Means of a Conventional Nodal Analysis Technique”. En: IEEE Transactions on Power Delivery. Vol. 14. No 3. Nueva York. Julio, 1999. pp 873-877. DOI: https://doi.org/10.1109/61.772327
G. Moreno, “Projeto de Aterramento de Subestações Combinando Métodos Simplificado e de duas Camadas”. En: I Seminário Internacional de Distribuição de Energia Elétrica. I SIDEE. Belo Horizonte. 1990.
C. Portela “Cálculo de parâmetros e comportamento de malhas de terra”. En: Aterramento em sistemas de potência. Rio de Janeiro. ABNT. 1983. pp 01-14.3.
S. Visacro, C. Portela. “Modelling of Earthing Systems for Lightning Protection Applications, Including Propagation Effects”. En: 21th International Conference on Lightning Protection, 21th ICLP. Berlín, 1992. pp 133- 138.
S. Visacro. “Evaluation of current and potential distribution for lightning protection system including the behavior of grounding electrodes”. En: 25th International Conference on Lightning Protection, 25th ICLP. Grecia, 2000. pp 464-468.
L.Grcev, M. Heimbach. “Grounding Systems Analysis in Transients Programs Applying Electromagnetic Field Approach”. En: IEEE Transactions on Power Delivery. Vol. 12. No 1. Nueva York. Enero, 1996. pp 186-193. DOI: https://doi.org/10.1109/61.568240
L. Grcev. “Computer Analysis of Transients Voltages in Large Grounding Systems”. En: IEEE Transactions on Power Delivery, Vol. 11, No 2, April, 1996.pp 815-821. DOI: https://doi.org/10.1109/61.489339
L. Grcev, M. Heimbach. “Frequency Dependent and Transient Characteristic of Substation Grounding Systems”. En: IEEE Transactions on Power Delivery. Vol. 12. No 1. Enero. 1996. pp 172-178. DOI: https://doi.org/10.1109/61.568238
H. Gómez, E. Velilla. “Modelación de Puestas a Tierra para Evaluación de Sobretensiones Transitorias”. Medellín. Proyecto de grado, Universidad de Antioquia. 2002.
J. Henao, H. Ramírez. “Variación de resistividad y permitividad de suelos con la frecuencia”. Medellín. Proyecto de grado, Universidad de Antioquia. 1990.
C. Portela. “RegimesTransitórios”. Rio de Janeiro. COPPE/UFRJ-Eletrobras. 1983.
G. Moreno, E. García, H. Gómez, E. Velilla, J. Valencia, J. Correa. “Modelación de puestas a tierra para evaluación de sobretensiones transitorias”. VI Congreso Latinoamericano y III iberoamericano en Alta Tensión y Aislamiento Eléctrico, ALTAE 2003. Costa Rica, 2003. pp 300-305.
E. Velilla, H. D. Gómez, G. Moreno, J. Valencia. “Assessing of grounding transient behavior and the Gtierras computer program”. International Conference on Grounding and Earthing, Ground’2004. Belo Horizonte, 2004.pp 160-164.
Downloads
Published
How to Cite
Issue
Section
License
Revista Facultad de Ingeniería, Universidad de Antioquia is licensed under the Creative Commons Attribution BY-NC-SA 4.0 license. https://creativecommons.org/licenses/by-nc-sa/4.0/deed.en
You are free to:
Share — copy and redistribute the material in any medium or format
Adapt — remix, transform, and build upon the material
Under the following terms:
Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
NonCommercial — You may not use the material for commercial purposes.
ShareAlike — If you remix, transform, or build upon the material, you must distribute your contributions under the same license as the original.
The material published in the journal can be distributed, copied and exhibited by third parties if the respective credits are given to the journal. No commercial benefit can be obtained and derivative works must be under the same license terms as the original work.