Reduction of matrix effects in pesticide residue analysis in food by programmable temperature vaporizer

Authors

  • Diego Alejandro AHUMADA FORIGUA Universidad Nacional de Colombia Sede Bogotá
  • Jairo Arturo GUERRERO DALLOS Universidad Nacional de Colombia Sede Bogotá https://orcid.org/0000-0001-9622-7741

DOI:

https://doi.org/10.17533/udea.vitae.11056

Keywords:

Pesticides, gas chromatography, food, mass spectrometry, residues

Abstract

Background: The phenomenon known as the “matrix-induced chromatographic response enhancement” commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection.
|Abstract
= 218 veces | PDF
= 60 veces|

Downloads

Download data is not yet available.

Author Biographies

Diego Alejandro AHUMADA FORIGUA, Universidad Nacional de Colombia Sede Bogotá

Facultad de Ciencias, Departamento de Química, Grupo de Residualidad y Destino Ambiental de Plaguicidas en Sistemas Agrícolas

Jairo Arturo GUERRERO DALLOS, Universidad Nacional de Colombia Sede Bogotá

Facultad de Ciencias, Departamento de Química, Grupo de Residualidad y Destino Ambiental de Plaguicidas en Sistemas Agrícolas

Downloads

Published

17-12-2013

How to Cite

AHUMADA FORIGUA, D. A., & GUERRERO DALLOS, J. A. (2013). Reduction of matrix effects in pesticide residue analysis in food by programmable temperature vaporizer. Vitae, 20(3), 184–1941. https://doi.org/10.17533/udea.vitae.11056

Issue

Section

Foods: Science, Engineering and Technology